Request a Quote
Auxiliary Equipment

Electric Steam Generator for Poultry Processing

An electric steam generator for poultry scalding and plant sanitation, configurable for approximately 100–500 kg of steam per hour and destination electrical standards.

Model
LDR Series
Planning Steam Output
100–500 kg/hour*
Reference Pressure
Up to approx. 0.7 MPa*
Heating Power
Approx. 72–360 kW*

* Planning, rated and reference values vary by product, configuration and operating conditions. Final data is confirmed in the technical proposal.

Share the raw material, incoming condition, target product, required output, local utilities and factory layout for engineering review.

PRODUCT OVERVIEW & WORKING PRINCIPLE

Project-sized electric steam supply for scalding and sanitation

The SIMPLOT electric steam generator provides steam for poultry scalding equipment and selected sanitation duties where the site electrical supply is suitable. Automatic water feed and control interlocks manage the documented operating sequence.

Planning outputs range from approximately 100 to 500 kg of steam per hour, with reference heating powers from 72 to 360 kW. Final output, pressure, electrical load, water treatment and regulatory classification must be confirmed for the destination site.

Electric Steam Generator for Poultry Processing - view 2
KEY FEATURES

Project-sized steam generation with safety-led configuration

The selected generator must match simultaneous steam demand, available electrical capacity, feed-water quality and destination pressure-equipment rules.

01

Multiple Output Sizes

Planning models cover approximately 100–500 kg/hour.

02

Automatic Water Feed

Supports controlled water replenishment.

03

Safety Interlocks

Documented functions include low-water and overpressure protection.

04

Electric Heating

Avoids on-site combustion at the generator.

05

Custom Electrical Design

Power, voltage, phases, controls and connection scope are project-specific.

TECHNICAL SPECIFICATIONS

Technical data and configuration

Values are reference information. Final specifications depend on capacity, product conditions and the approved project layout.

ModelLDR Series
Planning Steam OutputApprox. 100–500 kg/hour*
Reference Working PressureUp to approx. 0.7 MPa*
Reference Heating PowerApprox. 72 / 144 / 288 / 360 kW*
ControlAutomatic water feed and PLC/microcomputer control*
SafetyLow-water, overtemperature and overpressure interlocks, configuration-dependent
Feed WaterWater quality and treatment to be confirmed
Electrical SupplySized for destination voltage, frequency and available load
CustomizationOutput, pressure, power, pumps, controls and steam connections
FREQUENTLY ASKED QUESTIONS

Before you request a proposal.

These answers cover common selection questions. Contact us for a review based on your actual project conditions.

From the simultaneous steam demand of connected equipment plus operating margin.

Yes, subject to available site power.

No. Regulatory classification varies by country and must be confirmed locally.

It depends on feed-water quality and the selected generator.
PROJECT CONFIGURATION

Confirm the right equipment
for your production line.

Share the raw material, final product, target output, utilities and factory layout for a matched proposal.